Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 17, 2022, 01:08 PM
  • 29 0559_29 0516_06172022_072229.mp4

Date
06/17/2022
W/O
956951
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01106
PipeID
P24588
Time
6:08 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10180
Sewer Name
29 19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_956951_TV29054_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0516
Downstream MH
29 0559
Dir. of Survey
Upstream
Length Surveyed
256.7 ft.
Total Length
256.7 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 29 0516 to 29 0559
MH: 29 0516MH: 29 0559upstream0 ft. AMH - Upstream Manhole, Survey Ends - 29 05590.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"1.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish43.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"49.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"70.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"142.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"154.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"253.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start256.7 ft. AMH - Downstream Manhole, Survey Begins - 29 0516256.7 ft. MWM - Water Mark, 5 %of cross sectional area256.7 ft. MWL - Water Level, 5 %of cross sectional area256.7 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    186.5 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (13)

DistanceCodeObservation
213.1TF
207.4TF
0AMH29 0516
0MWM
0MWL
102.1TF
113.8TF
255.8TFC
3.4CM
255CM
0MGOCONNECTION AT MH 9 O'CLOCK
186.5TB
256.7AMH29 0559

Properties (7)

additional_info
630074061722061
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2022-06-17T06:08:26-07:00
documentation
PROPIPE
is_lateral_inspection
false