Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 17, 2022, 01:23 PM
  • 29 0516A_29 0516_06172022_074401.mp4

Date
06/17/2022
W/O
956951
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01106
PipeID
P24566
Time
6:23 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10180
Sewer Name
29 19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_956951_TV29054_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0516
Downstream MH
29 0516A
Dir. of Survey
Upstream
Length Surveyed
285.2 ft.
Total Length
285.2 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 29 0516 to 29 0516A
MH: 29 0516MH: 29 0516Aupstream0 ft. ACOM - Cleanout Mainline, Survey Ends - 29 0516A1.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"11.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"37.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"83.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"113.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"160.3 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES268.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start285.2 ft. AMH - Downstream Manhole, Survey Begins - 29 0516285.2 ft. MWM - Water Mark, 5 %of cross sectional area285.2 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (4)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    16.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    124.9 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    248 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    273.4 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (12)

DistanceCodeObservation
248TB
0AMH29 0516
171.9TF
0MWM
283.3CM
16.3CM
201.3TF
124.9FM
285.2ACOM29 0516A
273.4TB
283TF
0MWL

Properties (7)

additional_info
630074061722061
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2022-06-17T06:23:32-07:00
documentation
PROPIPE
is_lateral_inspection
false