18 0627_18 0625_07202022_010758.mp4
441.2 ft. - Crack Circumferential, from 12 to 12 o'clock, within 8 inches of joint: YES
447.1 ft. - Crack Spiral, from 10 to 12 o'clock, within 8 inches of joint: YES
499 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start
503.2 ft. - Crack Longitudinal Hinge, 2, from 03 to 09 o'clock, within 8 inches of joint: YES, Start
641.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
641.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
641.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
| Distance | Code | Observation |
|---|---|---|
| 676.3 | AMH | 18 0625, RUN LIST STATES MH AT 637' |
| 641.1 | SRV | — |
| 593.3 | CH2 | — |
| 441.2 | CC | — |
| 447.1 | CS | — |
| 674 | SAP | — |
| 641.1 | MMC | — |
| 503.2 | CL | — |
| 499 | CL | — |
| 503.2 | CH2 | — |
| 676.3 | MGO | CONNECTION AT MH 9 O'CLOCK |
| 674 | SRV | — |
| 0 | MWM | — |
| 0 | MWL | — |
| 112.1 | DSZ | DEBRIS |
| 674 | SSS | — |
| 641.1 | SAP | — |
| 674 | DSZ | — |
| 641.1 | SSS | — |
| 0 | AMH | 18 0627 |