- Date
- 06/28/2022
- W/O
- 956993
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00092
- PipeID
- P08918
- Time
- 3:04 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10211
- Sewer Name
- B JOINT OUTFALL B - UNIT 5B
- City
- ARCADIA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- RFIR_WO_956993_TV15053_JUN2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 21 in.
- Width
- 57 in.
- Upstream MH
- B 0406
- Downstream MH
- B 0405
- Dir. of Survey
- Downstream
- Length Surveyed
- 128 ft.
- Total Length
- 128 ft.
- Structural Index
- 3
- Structural Quick
- 3C2B
- Structural Rating
- 89
- O&M Index
- 2
- O&M Quick
- 413B
- O&M Rating
- 96
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 185
Pipe schematic from manhole B 0406 to B 0405 Observation photos (5)

0 ft. - General Observation - COCKROACHES IN MANHOLE

32.5 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

43.9 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

82.7 ft. - General Observation - MAG COATING

128 ft. - General Observation - COCKROACHES IN MANHOLE