- Date
- 06/27/2022
- W/O
- 956731
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00218
- PipeID
- P01316
- Time
- 9:26 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10190
- Sewer Name
- 01 SOUTH PARK AVENUE TRUNK
- City
- SOUTH LOS ANGELES
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- RFIR_WO_956731_TV01204_JUN2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 18 in.
- Upstream MH
- 01 0268
- Downstream MH
- 01 0267
- Dir. of Survey
- Downstream
- Length Surveyed
- 329.3 ft.
- Total Length
- 329.3 ft.
- Structural Index
- 3
- Structural Quick
- 4L2L
- Structural Rating
- 394
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 130
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 524
Pipe schematic from manhole 01 0268 to 01 0267 Observation photos (2)

2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

3.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES