Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 28, 2022, 08:10 AM
  • 01 0256_01 0255_06282022_022009.mp4

Date
06/28/2022
W/O
956731
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00218
PipeID
P01302
Time
1:10 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10190
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
SOUTH LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_956731_TV01204_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Square
Height
18 in.
Width
27 in.
Upstream MH
01 0256
Downstream MH
01 0255
Dir. of Survey
Downstream
Length Surveyed
287.6 ft.
Total Length
287.6 ft.
Structural Index
2
Structural Quick
2V00
Structural Rating
228
O&M Index
2
O&M Quick
2J00
O&M Rating
114
Overall Index
2
Overall Quick
Overall Rating
342
Pipe schematic from manhole 01 0256 to 01 0255
MH: 01 0256MH: 01 0255downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 02560 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MWLS - Water Level, Sag in pipe, 5 %of cross sectional area, Start2.1 ft. MGO - General Observation - PIPE IS LINED77.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN285 ft. MWLS - Water Level, Sag in pipe, 5 %of cross sectional area, Finish285 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish287.6 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE287.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0255

Observations (11)

DistanceCodeObservation
2.1MGOPIPE IS LINED
287.6MGOCONN @ MH 3 O'CLOCK/ACTIVE
2DAGS
0MWM
77.5TFOPEN
0AMH01 0256
287.6AMH01 0255
285MWLS
285DAGS
2MWLS
0MWL

Properties (7)

additional_info
630074062722201
custom_field_three
RFIR NO SEVERE DEFECTS-PIPE IS LINED
custom_field_two
3
customer
1
datetime
2022-06-28T01:10:48-07:00
documentation
PROPIPE
is_lateral_inspection
false