Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 28, 2022, 10:13 AM
  • 01 1404_01 0236_06282022_041935.mp4

Date
06/28/2022
W/O
956731
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00218
PipeID
P01282
Time
3:13 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10190
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
SOUTH LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_956731_TV01204_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
12 in.
Upstream MH
01 1404
Downstream MH
01 0236
Dir. of Survey
Downstream
Length Surveyed
136 ft.
Total Length
136 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2D00
O&M Rating
52
Overall Index
2
Overall Quick
Overall Rating
52
Pipe schematic from manhole 01 1404 to 01 0236
MH: 01 1404MH: 01 0236downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 01 14042 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.2 ft. MGO - General Observation - PIPE IS LINED10.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"73.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN119.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN133 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish136 ft. AMH - Downstream Manhole, Survey Ends - 01 0236

Observations (11)

DistanceCodeObservation
0MWL
2.2MGOPIPE IS LINED
2DAGS
119.4TFOPEN
0MWM
10.5TFA
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
133DAGS
73.9TFOPEN
136AMH01 0236
0AMH01 1404

Properties (7)

additional_info
630074062722201
custom_field_three
RFIR NO SEVERE DEFECTS-PIPE IS LINED
custom_field_two
3
customer
1
datetime
2022-06-28T03:13:25-07:00
documentation
PROPIPE
is_lateral_inspection
false