Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 29, 2022, 07:22 AM
  • 01 0233A_01 0233_06292022_013035.mp4

Date
06/29/2022
W/O
956731
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00218
PipeID
P01277
Time
12:22 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10192
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
SOUTH LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_956731_TV01204_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
12 in.
Upstream MH
01 0233A
Downstream MH
01 0233
Dir. of Survey
Downstream
Length Surveyed
306 ft.
Total Length
306 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2K00
O&M Rating
120
Overall Index
2
Overall Quick
Overall Rating
120
Pipe schematic from manhole 01 0233A to 01 0233
MH: 01 0233AMH: 01 0233downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 0233A0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - PIPE IS LINED210.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN303 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish305 ft. MGO - General Observation - ROACHES @ MH306 ft. AMH - Downstream Manhole, Survey Ends - 01 0233

Observations (10)

DistanceCodeObservation
2DAGS
2.1MGOPIPE IS LINED
0MWM
303DAGS
0MWL
0AMH01 0233A
306AMH01 0233
305MGOROACHES @ MH
210.7TFOPEN
0MGOCONN @ MH 9 O'CLOCK/ACTIVE

Properties (7)

additional_info
630074062822202
custom_field_three
RFIR NO SEVERE DEFECTS-PIPE IS LINED
custom_field_two
3
customer
1
datetime
2022-06-29T00:22:30-07:00
documentation
PROPIPE
is_lateral_inspection
false