Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 30, 2022, 06:32 AM
  • 19 0214_19 0213_06302022_004458.mp4

Date
06/29/2022
W/O
956995
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00718
PipeID
P15183
Time
11:32 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10194
Sewer Name
19 ARTESIA-CERRITOS TRUNK
City
CERRITOS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_956995_TV19059_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
19 0214
Downstream MH
19 0213
Dir. of Survey
Downstream
Length Surveyed
262.9 ft.
Total Length
262.9 ft.
Structural Index
3
Structural Quick
4E3C
Structural Rating
274
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
274
Pipe schematic from manhole 19 0214 to 19 0213
MH: 19 0214MH: 19 0213downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 19 02140 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start17.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"76.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"86.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"105.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"128.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"139.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"147.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish168.7 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES172.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start182 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"192.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"227.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"260 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish260 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish262.9 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK262.9 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK262.9 ft. AMH - Downstream Manhole, Survey Ends - 19 0213

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    172.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (23)

DistanceCodeObservation
192.6TF
128.3TFC
262.9MGOCONNECTION AT MH 9 O'CLOCK
227.6TFC
86.9TF
182TF
0MGOCONNECTION AT MH 9 O'CLOCK
168.7CM
17.2TFC
172.8CM
0AMH19 0214
147.9FM
260CM
3.9FM
260SSS
262.9MGOCONNECTION AT MH 3 O'CLOCK
262.9AMH19 0213
2SSS
0MWL
76.4TF
0MWM
139.2TFA
105.6TF

Properties (7)

additional_info
630074062922202
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2022-06-29T23:32:26-07:00
documentation
PROPIPE
is_lateral_inspection