Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 4, 2022, 09:57 AM
  • F 0026_F OO25_842022_030926.mp4

Date
08/04/2022
W/O
0962090
Weather
Dry
Operator/Surveyor
MMARTIN
Sewer ID
Z00033
PipeID
P10116
Time
2:57 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3168
Sewer Name
F JOINT OUTFALL F - UNIT 1
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
01
Purpose
Capital Improvement Program Assesment
Project
20220804MDM_JOINT_OUTFALL_F_UNIT_1
Material
Reinforced Concrete Pipe
Shape
Circular
Height
69 in.
Upstream MH
F 0026
Downstream MH
F OO25
Dir. of Survey
Downstream
Length Surveyed
252.8 ft.
Total Length
252.8 ft.
Structural Index
4
Structural Quick
5241
Structural Rating
16
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
16
Pipe schematic from manhole F 0026 to F OO25
MH: F 0026MH: F OO25downstream0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 3:00AM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LOMG CIRCUM REBAR CORRODED MISSING2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2.2 ft. MGO - General Observation - MAG COAT 30%118.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR252.2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG252.2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR CORRODED MISSING252.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE252.8 ft. AMH - Downstream Manhole, Survey Ends - 2:25AM

Observation photos (5)

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LOMG CIRCUM REBAR CORRODED MISSING

    2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LOMG CIRCUM REBAR CORRODED MISSING

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 30%

    2.2 ft. - General Observation - MAG COAT 30%

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

    118.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

Observations (14)

DistanceCodeObservation
0MGOConn. @ Mh, 9 O' Clock. OPEN
252.2SAMSEVERE AGG
0MGOConn. @ Mh, 3 O' Clock. ACTIVE
0AMH3:00AM
252.8AMH2:25AM
0MWM
252.2SRCLONG CIRCUM REBAR CORRODED MISSING
252.2SSSBLISTERING PEELING CONCRETE
2SRCLOMG CIRCUM REBAR CORRODED MISSING
0MWL
2SSSBLISTERING PEELING CONCRETE
2.2MGOMAG COAT 30%
118.2SRCBROKEN MISSING REBAR
2SAMSEVERE AGG

Properties (6)

custom_field_three
LONG CIRCUM REBAR CORRODED MISSING
custom_field_two
1
customer
LACSD
datetime
2022-08-04T02:57:23-07:00
documentation
MARTIN,OLIVER 111,BRAR,
is_lateral_inspection
false