Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 3, 2022, 11:21 AM
  • B 0412_B 0411_832022_042648.mp4

Date
08/03/2022
W/O
0970275
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00092
PipeID
P08924
Time
4:21 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3167R
Sewer Name
B JOINT OUTFALL B - UNIT 5B
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
03
Purpose
Maintenance Related
Project
20220803MDM_JOINT_OUTFALL_B_UNIT_5B
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
B 0412
Downstream MH
B 0411
Dir. of Survey
Downstream
Length Surveyed
367.1 ft.
Total Length
367.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole B 0412 to B 0411
MH: B 0412MH: B 0411downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:40AM289.1 ft. RTC - Roots Tap Connection, from 01 to 05 o'clock, 10 %, within 8 inches of joint: YES367.1 ft. AMH - Downstream Manhole, Survey Ends - 4:55AM

Observation photos (1)

  • Roots Tap Connection, from 01 to 05 o'clock, 10 %, within 8 inches of joint: YES

    289.1 ft. - Roots Tap Connection, from 01 to 05 o'clock, 10 %, within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
0MWL
289.1RTC
367.1AMH4:55AM
0MWM
0AMH4:40AM

Properties (5)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2022-08-03T04:21:52-07:00
documentation
MARTIN,BRAR,CASTILLO
is_lateral_inspection
false