Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 8, 2022, 03:36 PM
  • 15 0262_15 0261_06082022_094922.mp4

Date
06/08/2022
W/O
951848
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00627
PipeID
P12185
Time
8:36 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10166
Sewer Name
15 SAN JOSE CREEK TRUNK
City
CITY OF INDUSRTY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Routine Assessment
Project
WO_951848_TV15133_MAY2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0262
Downstream MH
15 0261
Dir. of Survey
Downstream
Length Surveyed
409.6 ft.
Total Length
409.6 ft.
Structural Index
2
Structural Quick
3O2P
Structural Rating
409
O&M Index
2
O&M Quick
2P00
O&M Rating
168
Overall Index
2
Overall Quick
Overall Rating
577
Pipe schematic from manhole 15 0262 to 15 0261
MH: 15 0262MH: 15 0261downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 02620 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - 25% MAG COAT2 ft. MWLS - Water Level, Sag in pipe, 5 %of cross sectional area, Start97.2 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"192.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN305.1 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"361.2 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"407 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish407 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish407 ft. MWLS - Water Level, Sag in pipe, 5 %of cross sectional area, Finish407 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish409.5 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ABANDONED409.6 ft. AMH - Downstream Manhole, Survey Ends - 15 0261

Observations (18)

DistanceCodeObservation
407SAV
2SSS
2SAV
407SSS
409.6AMH15 0261
2DAGS
192.7TBOPEN
407MWLS
0MWL
2MGO25% MAG COAT
407DAGS
305.1TBC
97.2TBC
409.5MGOCONN @ MH 3 O'CLOCK/ABANDONED
0AMH15 0262
0MWM
361.2TBC
2MWLS

Properties (7)

additional_info
630074060822061
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2022-06-08T08:36:07-07:00
documentation
PROPIPE
is_lateral_inspection
false