- Date
- 04/29/2022
- W/O
- 951820
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00578
- PipeID
- P18512
- Time
- 1:02 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10084
- Sewer Name
- 14 TRUNK "B"
- City
- LANCASTER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- RFIR_WO_951820_TV14019_MAY2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 14 0428
- Downstream MH
- 14 0427
- Dir. of Survey
- Downstream
- Length Surveyed
- 339.8 ft.
- Total Length
- 339.8 ft.
- Structural Index
- 3
- Structural Quick
- 3L2L
- Structural Rating
- 333
- O&M Index
- 2
- O&M Quick
- 4631
- O&M Rating
- 161
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 494
Pipe schematic from manhole 14 0428 to 14 0427 Observation photos (4)

2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

8.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

69.2 ft. - Tap Saddle Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"

250.6 ft. - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES