- Date
- 06/28/2022
- W/O
- 956784
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00206
- PipeID
- P01035
- Time
- 10:34 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10191
- Sewer Name
- 01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
- City
- LOS ANGELES
- Loc. details
- Alley
- Location Code
- H
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- RFIR_WO_956784_TV01015_JUN2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 15 in.
- Upstream MH
- 01 0546
- Downstream MH
- 01 0325A
- Dir. of Survey
- Downstream
- Length Surveyed
- 276.7 ft.
- Total Length
- 276.7 ft.
- Structural Index
- 4
- Structural Quick
- 4J00
- Structural Rating
- 216
- O&M Index
- 2
- O&M Quick
- 2800
- O&M Rating
- 16
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 232
Pipe schematic from manhole 01 0546 to 01 0325A Observation photos (3)

3.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

183.4 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

233.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start