Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 28, 2022, 11:31 AM
  • 18 0971_18 0970_7282022_043428.mp4

Date
07/28/2022
W/O
0962316
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00716
PipeID
P14821
Time
4:31 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3162R
Sewer Name
18 WORSHAM CREEK TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
11
Purpose
Maintenance Related
Project
20220728MDM_WORSHAM_CREEK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
7.519999980926514 in.
Upstream MH
18 0971
Downstream MH
18 0970
Dir. of Survey
Downstream
Length Surveyed
326 ft.
Total Length
326 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3311
O&M Rating
10
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 18 0971 to 18 0970
MH: 18 0971MH: 18 0970downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:35AM0 ft. MWL - Water Level, 5 %of cross sectional area59.4 ft. RMC - Roots Medium Connection, from 08 to 12 o'clock, 25 %, within 8 inches of joint: NO81.5 ft. RMC - Roots Medium Connection, from 09 to 11 o'clock, 5 %, within 8 inches of joint: NO209.9 ft. RMC - Roots Medium Connection, from 12 to 04 o'clock, 25 %, within 8 inches of joint: NO276.2 ft. RFC - Roots Fine Connection, from 09 to 12 o'clock, within 8 inches of joint: NO - 2%326 ft. AMH - Downstream Manhole, Survey Ends - 5:15AM

Observation photos (1)

  • Roots Medium Connection, from 08 to 12 o'clock, 25 %, within 8 inches of joint: NO

    59.4 ft. - Roots Medium Connection, from 08 to 12 o'clock, 25 %, within 8 inches of joint: NO

Observations (8)

DistanceCodeObservation
0MWM
59.4RMC
326AMH5:15AM
81.5RMC
0AMH4:35AM
209.9RMC
0MWL
276.2RFC2%

Properties (6)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2022-07-28T04:31:17-07:00
documentation
MARTIN,BRAR,CASTILLO
is_lateral_inspection
false
lining
PVCP