2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - General Observation - MAG COAT 10%
2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR
78.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR
97.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
149 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - BROKEN REBAR
386.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
| Distance | Code | Observation |
|---|---|---|
| 97.1 | SRC | BROKEN MISSING REBAR |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 0 | AMH | 3:55AM |
| 0 | MWM | — |
| 2 | MGO | MAG COAT 10% |
| 2 | SAM | SEVERE AGG |
| 78.6 | SRC | LONG CIRCUM REBAR |
| 386.1 | SRC | BROKEN MISSING REBAR |
| 538.1 | SAM | SEVERE AGG |
| 0 | MWL | — |
| 2 | SRC | LONG CIRCUM REBAR |
| 149 | SRC | BROKEN REBAR |
| 538.7 | AMH | 4:40AM |
| 538.1 | SSS | BLISTERING PEELING CONCRETE |
| 538.1 | SRC | LONG CIRCUM REBAR CORRODED MISSING |