18 0614_18 0918_772022_041856.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
2 ft. - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: NO - LONG REBAR
2 ft. - Surface Reinforcement Corroded, from 10 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR
4.8 ft. - Surface Reinforcement Corroded, from 10 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR
15.4 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
30.7 ft. - Surface Aggregate Missing, from 02 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG
33.5 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG
33.5 ft. - Surface Reinforcement Corroded, from 08 to 10 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR
37.5 ft. - Surface Reinforcement Corroded, at 09 o'clock, within 8 inches of joint: NO - LONG REBAR
53.7 ft. - Surface Reinforcement Corroded, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR SPORATIC
92.9 ft. - Surface Reinforcement Corroded, at 09 o'clock, within 8 inches of joint: YES, Start - LONG REBAR
107.7 ft. - Surface Reinforcement Corroded, from 08 to 10 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
108.9 ft. - Surface Reinforcement Corroded, from 08 to 01 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR
147.9 ft. - Surface Reinforcement Corroded, from 08 to 10 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR
154.5 ft. - Surface Reinforcement Corroded, from 08 to 10 o'clock, within 8 inches of joint: NO
182.9 ft. - Surface Reinforcement Corroded, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
184.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
253.8 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
258.2 ft. - Surface Reinforcement Corroded, from 09 to 10 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
306.9 ft. - Surface Reinforcement Corroded, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - LONG REBAR
362.5 ft. - Surface Reinforcement Corroded, from 08 to 10 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
| Distance | Code | Observation |
|---|---|---|
| 433.2 | SSS | BLISTERING PEELING CONCRETE |
| 39.7 | SRC | CIRCUM REBAR |
| 15.4 | SRC | CIRCUM REBAR |
| 108.9 | SRC | LONG CIRCUM REBAR |
| 7.3 | SRC | LONG CIRCUM REBAR |
| 258.2 | SRC | CIRCUM REBAR |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 362.5 | SRC | CIRCUM REBAR |
| 37.5 | SRC | LONG REBAR |
| 2 | SAV | SEVERE AGG SPORATIC |
| 33.5 | SAM | SEVERE AGG |
| 200.2 | SRC | CIRCUM REBAR |
| 182.9 | SRC | CIRCUM REBAR |
| 147.9 | SRC | LONG CIRCUM REBAR |
| 433.2 | SAM | SEVERE AGG |
| 0 | AMH | 4:15AM |
| 433.9 | AMH | 5:15AM |
| 154.5 | SRC | — |
| 2 | SRC | LONG REBAR |
| 2 | SRC | LONG CIRCUM REBAR |
| 100.2 | SRC | LONG REBAR |
| 433.2 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 100.2 | SRC | CIRCUM REBAR |
| 12.1 | TF | Open |
| 121 | SRC | LONG CIRCUM REBAR |
| 33.5 | SRC | CIRCUM REBAR |
| 324.5 | SRC | LONG REBAR |
| 4.8 | SRC | LONG CIRCUM REBAR |
| 107.7 | SRC | CIRCUM REBAR |
| 53.7 | SRC | CIRCUM REBAR SPORATIC |
| 184.5 | SRC | CIRCUM REBAR |
| 433.2 | SAV | SEVERE AGG |
| 173.1 | SRC | LONG CIRCUM REBAR |
| 30.7 | SAM | SEVERE AGG |
| 0 | MWM | — |
| 0 | MWL | — |
| 253.8 | SRC | CIRCUM REBAR |
| 306.9 | SRC | LONG REBAR |
| 92.9 | SRC | LONG REBAR |