18 0615_18 0614_772022_031337.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR
2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Change - SEVERE AGG
4.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
16 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE
19.7 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
27.4 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR
66.2 ft. - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
109 ft. - Surface Reinforcement Corroded, from 01 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
151.6 ft. - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
164.4 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR
176.8 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: YES, Start - LONG REBAR
| Distance | Code | Observation |
|---|---|---|
| 16 | SSS | BLISTERING PEELING CONCRETE |
| 27.4 | SRC | LONG REBAR |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 0 | AMH | 3:10AM |
| 181.3 | SRC | LONG REBAR |
| 240.8 | AMH | 3:40AM |
| 66.2 | SRC | CIRCUM REBAR |
| 151.6 | SRC | CIRCUM REBAR |
| 2 | SRC | LONG CIRCUM REBAR |
| 176.8 | SRC | LONG REBAR |
| 0 | MWL | — |
| 19.7 | SAV | SEVERE AGG SPORATIC |
| 2 | SAM | SEVERE AGG |
| 0 | MWM | — |
| 0 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 109 | SRC | CIRCUM REBAR |
| 240.3 | SSS | BLISTERING PEELING CONCRETE |
| 164.4 | SRC | LONG REBAR |
| 4.2 | SAV | SEVERE AGG SPORATIC |
| 240.3 | SAM | SEVERE AGG SPORATIC |