Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 6, 2022, 08:04 PM
  • B 0016_B 0925_06062022_141019.mp4

Date
06/06/2022
W/O
951856
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00072
PipeID
P20088
Time
1:04 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10164
Sewer Name
B JOINT OUTFALL B - UNIT 1A
City
CARSON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_951856_TV30027_MAY2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
144 in.
Width
144 in.
Upstream MH
B 0016
Downstream MH
B 0925
Dir. of Survey
Downstream
Length Surveyed
21.5 ft.
Total Length
21.5 ft.
Structural Index
4
Structural Quick
5434
Structural Rating
32
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
32
Pipe schematic from manhole B 0016 to B 0925
MH: B 0016MH: B 0925downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 00160 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start21.5 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish21.5 ft. AMH - Downstream Manhole, Survey Ends - B 092521.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK21.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
21.5SRV
2SRV
21.5AMHB 0925
0AMHB 0016
0MWL
0MWM
21.5MGOCONNECTION AT MH 3 O'CLOCK
2SAP
21.5SAP

Properties (8)

additional_info
630098060622001
custom_field_three
REINFORCEMENT VISIBLE/AGGREGATE PROJECTING
custom_field_two
2
customer
1
datetime
2022-06-06T13:04:26-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
33381