Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 1, 2022, 05:07 AM
  • 18 1005_18 1004_06302022_232727.mp4

Date
06/30/2022
W/O
957915
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00677
PipeID
P14859
Time
10:07 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10197
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 1
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_957915_TV18210
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1005
Downstream MH
18 1004
Dir. of Survey
Downstream
Length Surveyed
281.4 ft.
Total Length
281.4 ft.
Structural Index
3
Structural Quick
4337
Structural Rating
43
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
44
Pipe schematic from manhole 18 1005 to 18 1004
MH: 18 1005MH: 18 1004downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 100516.1 ft. FM - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES23.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"25.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"30.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES51.6 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES57.6 ft. FC - Fracture Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES78.5 ft. CS - Crack Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES82.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"84.1 ft. RFJ - Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES85.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"99 ft. FC - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES131.4 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES143.3 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES144.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"150 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"150.3 ft. FS - Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES187.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES205.7 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES210 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"214.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES215.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"220.1 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES264.9 ft. FS - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES268.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES269.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"274.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"281.4 ft. AMH - Downstream Manhole, Survey Ends - 18 1004

Observation photos (16)

  • Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    16.1 ft. - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    30.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    51.6 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES

    57.6 ft. - Fracture Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

    78.5 ft. - Crack Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES

    84.1 ft. - Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

    99 ft. - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    131.4 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

    143.3 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES

    150.3 ft. - Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    187.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    205.7 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    214.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    220.1 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

    264.9 ft. - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    268.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (30)

DistanceCodeObservation
281.4AMH18 1004
99FC
84.1RFJ
210TF
51.6CM
0MWL
220.1CM
205.7CL
274.8TF
150.3FS
16.1FM
23.6TF
85.5TF
264.9FS
0MWM
57.6FC
131.4CL
144.4TF
215.4TF
25.9TF
214.5FM
82.5TF
0AMH18 1005
269.3TF
150TF
78.5CS
187.8CM
30.6CM
268.1FM
143.3FS

Properties (7)

additional_info
630074063022211
custom_field_three
MULTIPLE FRACTURE'S/ CRACKS
custom_field_two
2
customer
1
datetime
2022-06-30T22:07:01-07:00
documentation
PROPIPE
is_lateral_inspection
false