Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 10, 2022, 09:32 AM
  • 02 0019A_02 0019_6102022_023345.mp4

Date
06/10/2022
W/O
0957066
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00234
PipeID
P03048
Time
2:32 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3114
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Capital Improvement Program Assesment
Project
20220609MDM_ARTESIA_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0019
Downstream MH
02 0019A
Dir. of Survey
Upstream
Length Surveyed
6.5 ft.
Total Length
6.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 02 0019 to 02 0019A
MH: 02 0019MH: 02 0019Aupstream0 ft. AMH - Upstream Manhole, Survey Ends - 2:40AM5.5 ft. MGO - General Observation - BRICKS IN POOR CONDITION IN STACK6.5 ft. MWL - Water Level, 10 %of cross sectional area6.5 ft. MWM - Water Mark, 20 %of cross sectional area6.5 ft. AMH - Downstream Manhole, Survey Begins - 2:35AM

Observation photos (1)

  • General Observation - BRICKS IN POOR CONDITION IN STACK

    1 ft. - General Observation - BRICKS IN POOR CONDITION IN STACK

Observations (5)

DistanceCodeObservation
0MWL
1MGOBRICKS IN POOR CONDITION IN STACK
0MWM
0AMH2:35AM
6.5AMH2:40AM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2022-06-10T02:32:59-07:00
documentation
MARTIN,REVELES,IGNACIO
is_lateral_inspection
false