- Date
- 06/09/2022
- W/O
- 0957066
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00234
- PipeID
- P03065
- Time
- 4:03 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H3114
- Sewer Name
- 02 ARTESIA EXTENSION TRUNK
- City
- BELLFLOWER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 39
- Purpose
- Capital Improvement Program Assesment
- Project
- 20220609MDM_ARTESIA_EXTENSION_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 02 0033
- Downstream MH
- 02 0032A
- Dir. of Survey
- Downstream
- Length Surveyed
- 143.9 ft.
- Total Length
- 143.9 ft.
- Structural Index
- 3
- Structural Quick
- 4138
- Structural Rating
- 46
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 50
Pipe schematic from manhole 02 0033 to 02 0032A Observation photos (4)

2.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING FFLAKING OUTER SURFACE

77.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

91.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

95 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL