Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 9, 2022, 11:03 AM
  • 02 0033_02 0032A_692022_041931.mp4

Date
06/09/2022
W/O
0957066
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00234
PipeID
P03065
Time
4:03 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3114
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Capital Improvement Program Assesment
Project
20220609MDM_ARTESIA_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0033
Downstream MH
02 0032A
Dir. of Survey
Downstream
Length Surveyed
143.9 ft.
Total Length
143.9 ft.
Structural Index
3
Structural Quick
4138
Structural Rating
46
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
50
Pipe schematic from manhole 02 0033 to 02 0032A
MH: 02 0033MH: 02 0032Adownstream0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:10AM0 ft. MWL - Water Level, 10 %of cross sectional area2.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING FFLAKING OUTER SURFACE5 ft. FC - Fracture Circumferential, from 08 to 01 o'clock, within 8 inches of joint: YES - SLIGHT6.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped10.5 ft. FC - Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES - SL14 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - HAIRLINE19.9 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H32.2 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL56.3 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H71 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - H77.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT77.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL77.7 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES, Start - SL83.5 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES, Finish - SL83.5 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SL86.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - SL91.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES95 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL98.1 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H102.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped106.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - SL122 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H133.6 ft. FC - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES - SL136.8 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H143.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - PEELING FLAKING OUTER SUFACE SPORATIC143.5 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN143.9 ft. AMH - Downstream Manhole, Survey Ends - 4:35AM

Observation photos (4)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING FFLAKING OUTER SURFACE

    2.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING FFLAKING OUTER SURFACE

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    77.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    91.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

    95 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

Observations (29)

DistanceCodeObservation
91.6SSS
5FCSLIGHT
0MWM
6.2TFCCapped
71FLH
77.7FMSLIGHT
98.1FLH
122FLH
86.2FLSL
77.7FLSL
56.3FCH
143.5SSSPEELING FLAKING OUTER SUFACE SPORATIC
106.6FLSL
143.9AMH4:35AM
77.7FLSL
14FLHAIRLINE
95FLSL
0AMH4:10AM
133.6FCSL
83.5FLSL
19.9FLH
143.5MGOConn. @ Mh, 3 O' Clock. OPEN
102.1TFCCapped
0MWL
136.8FCH
2.2SSSPEELING FFLAKING OUTER SURFACE
32.2FCSL
83.5FCSL
10.5FCSL

Properties (6)

custom_field_three
LONG SLIGHT FRACTURE JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2022-06-09T04:03:17-07:00
documentation
MARTIN,REVELES,OLIVER 111,IGNACIO
is_lateral_inspection
false