Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 17, 2022, 11:22 AM
  • 08 0131_08 0130_6172022_042737.mp4

Date
06/17/2022
W/O
0957191
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00006
PipeID
P00187
Time
4:22 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3122
Sewer Name
08 FIGUEROA STREET TRUNK
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Capital Improvement Program Assesment
Project
20220617MDM_FIGUEROA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
08 0131
Downstream MH
08 0130
Dir. of Survey
Downstream
Length Surveyed
274.7 ft.
Total Length
274.7 ft.
Structural Index
2
Structural Quick
332A
Structural Rating
31
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
31
Pipe schematic from manhole 08 0131 to 08 0130
MH: 08 0131MH: 08 0130downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:40AM33.5 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE58.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open64.3 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - HAIRLINE80.3 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SLIGHT96.5 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL109.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped111.3 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL111.3 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H151.8 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H160.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped162.5 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H182.7 ft. FC - Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES - SL207.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open217.5 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL242.1 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SL246.1 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - SL258.1 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H259.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open260.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL274.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped274.7 ft. AMH - Downstream Manhole, Survey Ends - 5:15AM

Observations (25)

DistanceCodeObservation
0MWM
0MGOConn. @ Mh, 3 O' Clock. OPEN
242.1FCSL
0MWL
160.7TFCCapped
207.9TFOpen
58.6TFOpen
33.5FCHAIRLINE
260.4FCSL
274.7AMH5:15AM
259.1TFOpen
109.5TFCCapped
258.1FCH
111.3FCSL
64.3FLHAIRLINE
111.3FLH
162.5FCH
0AMH4:40AM
246.1FLSL
151.8FCH
80.3FCSLIGHT
182.7FCSL
217.5FCSL
96.5FCSL
274.2MGOConn. @ Mh, 3 O' Clock. Capped

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2022-06-17T04:22:47-07:00
documentation
MARTIN,REVELES,IGNACIO
is_lateral_inspection
false