Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 17, 2022, 09:35 AM
  • 08 0135_08 0134_6172022_024315.mp4

Date
06/17/2022
W/O
0957191
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00006
PipeID
P00191
Time
2:35 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3122
Sewer Name
08 FIGUEROA STREET TRUNK
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Capital Improvement Program Assesment
Project
20220617MDM_FIGUEROA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
08 0135
Downstream MH
08 0134
Dir. of Survey
Downstream
Length Surveyed
380.9 ft.
Total Length
380.9 ft.
Structural Index
2
Structural Quick
5135
Structural Rating
44
O&M Index
1
O&M Quick
2213
O&M Rating
7
Overall Index
2
Overall Quick
Overall Rating
51
Pipe schematic from manhole 08 0135 to 08 0134
MH: 08 0135MH: 08 0134downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:40AM2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start - HOT FLOW STREAMY2 ft. MGO - General Observation - HOT FLOW24.3 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT32.4 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - HAIRLINE33.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped58.8 ft. RFJ - Roots Fine Joint, from 11 to 01 o'clock, within 8 inches of joint: YESR - 1%83.3 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H83.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open89.7 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H133.9 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL133.9 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H134.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped160.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO168.6 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - H185.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped211.2 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H219.4 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SL236.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped254 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H286.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H289.8 ft. RFJ - Roots Fine Joint, from 11 to 01 o'clock, within 8 inches of joint: YESR - 1%294.3 ft. RFJ - Roots Fine Joint, from 10 to 02 o'clock, within 8 inches of joint: YESR - 1%306.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H310.3 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SL314.2 ft. B - Broken, at 11 o'clock, within 8 inches of joint: YES - LONG SLIGHT FRACTURE OFFSET314.2 ft. B - Broken, from 12 to 04 o'clock, within 8 inches of joint: YES - SLIGHT CIRCUM FRACTURE OFFSET317.9 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H342.4 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SL374.6 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H380.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN380.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish - HOT STREAMY FLOW380.9 ft. AMH - Downstream Manhole, Survey Ends - 3:25AM

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start - HOT FLOW STREAMY

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start - HOT FLOW STREAMY

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: NO

    160.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO

  • Broken, at 11 o'clock, within 8 inches of joint: YES - LONG SLIGHT FRACTURE OFFSET

    314.2 ft. - Broken, at 11 o'clock, within 8 inches of joint: YES - LONG SLIGHT FRACTURE OFFSET

  • Broken, from 12 to 04 o'clock, within 8 inches of joint: YES - SLIGHT CIRCUM FRACTURE OFFSET

    314.2 ft. - Broken, from 12 to 04 o'clock, within 8 inches of joint: YES - SLIGHT CIRCUM FRACTURE OFFSET

Observations (35)

DistanceCodeObservation
33.4TFCCapped
380.2MGOConn. @ Mh, 3 O' Clock. OPEN
317.9FCH
24.3FCSLIGHT
2DAGSHOT FLOW STREAMY
89.7FCH
211.2FLH
133.9FCSL
168.6FCH
380.9AMH3:25AM
294.3RFJ1%
306.5FCH
342.4FCSL
380.2DAGSHOT STREAMY FLOW
0MWM
310.3FCSL
2MGOHOT FLOW
134.8TFCCapped
133.9FCH
254FLH
83.8TFOpen
0MWL
219.4FLSL
236.5TFCCapped
374.6FCH
83.3FCH
314.2BLONG SLIGHT FRACTURE OFFSET
0AMH2:40AM
286.4FLH
32.4FCHAIRLINE
185.7TFCCapped
160.4DAGS
289.8RFJ1%
314.2BSLIGHT CIRCUM FRACTURE OFFSET
58.8RFJ1%

Properties (6)

custom_field_three
BROKEN PIPE -SLIGHT LONG&CIRCUM FRACTURE OFFSET
custom_field_two
2
customer
LACSD
datetime
2022-06-17T02:35:01-07:00
documentation
MARTIN,REVELES,IGNACIO
is_lateral_inspection
false