Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 21, 2022, 08:21 AM
  • C 0288_C 0287_6212022_015340.mp4

Date
06/21/2022
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00134
PipeID
P09748
Time
1:21 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3126
Sewer Name
C JOINT OUTFALL C - UNIT 6E
City
HAWAIIAN GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
13
Purpose
Maintenance Related
Project
20220621MDM_JOINT_OUTFALL_UNIT_6E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
C 0288
Downstream MH
C 0287
Dir. of Survey
Downstream
Length Surveyed
47.9 ft.
Total Length
47.9 ft.
Structural Index
4
Structural Quick
5441
Structural Rating
26
O&M Index
3
O&M Quick
4331
O&M Rating
17
Overall Index
4
Overall Quick
Overall Rating
43
Pipe schematic from manhole C 0288 to C 0287
MH: C 0288MH: C 0287downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:25AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLSTERING PEELING CONCRETE8.7 ft. SRC - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR SPORATIC25.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start25.5 ft. MWM - Water Mark, 70 %of cross sectional area33.2 ft. IR - Infiltration Runner, from 10 to 02 o'clock, within 8 inches of joint: YES44.3 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - MISSING REBAR CORROSION BEYOUND REBAR45.3 ft. SRC - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR SPORATIC45.3 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, - CIRCUM REBAR CORRODED & MISSING47 ft. RMB - Roots Medium Barrell, from 11 to 01 o'clock, 5 %, within 8 inches of joint: NO47 ft. ID - Infiltration Dripper, from 10 to 02 o'clock, within 8 inches of joint: NO47 ft. HVV - Hole Void Visible, from 12 to 01 o'clock, within 8 inches of joint: NO47 ft. MGO - General Observation - ZOOM APPOX 10' DOWNSTREAM POSSIBLE SPOIL VISIBLE47.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish47.4 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG47.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE47.9 ft. MSA - Survey Abandoned - SINKHOLE INSPECTION COMPLETE

Observation photos (9)

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLSTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLSTERING PEELING CONCRETE

  • Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR SPORATIC

    8.7 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR SPORATIC

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    25.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - MISSING REBAR CORROSION BEYOUND REBAR

    44.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - MISSING REBAR CORROSION BEYOUND REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES,  - CIRCUM REBAR CORRODED & MISSING

    45.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, - CIRCUM REBAR CORRODED & MISSING

  • Roots Medium Barrell, from 11 to 01 o'clock, 5 %, within 8 inches of joint: NO

    47 ft. - Roots Medium Barrell, from 11 to 01 o'clock, 5 %, within 8 inches of joint: NO

  • Hole Void Visible, from 12 to 01 o'clock, within 8 inches of joint: NO

    47 ft. - Hole Void Visible, from 12 to 01 o'clock, within 8 inches of joint: NO

  • General Observation - ZOOM APPOX 10' DOWNSTREAM POSSIBLE SPOIL VISIBLE

    47 ft. - General Observation - ZOOM APPOX 10' DOWNSTREAM POSSIBLE SPOIL VISIBLE

Observations (20)

DistanceCodeObservation
47RMB
25.5DAGS
47ID
0MWM
25.5MWM
44.3SRCMISSING REBAR CORROSION BEYOUND REBAR
2SAMSEVERE AGG
47HVV
47MGOZOOM APPOX 10' DOWNSTREAM POSSIBLE SPOIL VISIBLE
47.9MSASINKHOLE INSPECTION COMPLETE
0AMH1:25AM
47.4DAGS
45.3SRCCIRCUM REBAR SPORATIC
47.4SAMSEVERE AGG
33.2IR
0MWL
8.7SRCCIRCUM REBAR SPORATIC
2SSSBLSTERING PEELING CONCRETE
47.4SSSBLISTERING PEELING CONCRETE
45.3SRCCIRCUM REBAR CORRODED & MISSING

Properties (5)

additional_info
SINKHOLE DOWNSTREAM MH# C288
customer
LACSD
datetime
2022-06-21T01:21:51-07:00
documentation
MARTIN,REVELES,OLIVER 111,IGNACIO
is_lateral_inspection
false