Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 26, 2022, 05:39 AM
  • 22 0630_22 0629_04252022_235835.mp4

Date
04/25/2022
W/O
951828
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00827
PipeID
P16978
Time
10:39 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10080
Sewer Name
22 SUNFLOWER TRUNK
City
GLENDORA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_951828_TV22166_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0630
Downstream MH
22 0629
Dir. of Survey
Downstream
Length Surveyed
368.7 ft.
Total Length
368.7 ft.
Structural Index
2
Structural Quick
3227
Structural Rating
20
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
20
Pipe schematic from manhole 22 0630 to 22 0629
MH: 22 0630MH: 22 0629downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 06300 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. SSS - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO0 ft. MWL - Water Level, 20 %of cross sectional area2.1 ft. MGO - General Observation - MAG COAT2.1 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start10.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"16.1 ft. SSS - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO, Start20 ft. SSS - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO, Finish31.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"42 ft. SSS - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO, Start46.1 ft. SSS - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO, Finish53.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"71.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"75.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"114.1 ft. SSS - Surface Spalling, from 02 to 03 o'clock, within 8 inches of joint: NO124.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"136.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"181.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"201.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"243 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"260.1 ft. SSS - Surface Spalling, from 01 to 03 o'clock, within 8 inches of joint: NO262.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"295.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"327.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"344.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"367 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish368.7 ft. AMH - Downstream Manhole, Survey Ends - 22 0629

Observation photos (1)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (28)

DistanceCodeObservation
0AMH22 0630
367SAV
0MWM
16.1SSS
260.1SSS
327.1TFC
71.4TFC
42SSS
262.4TF
31.1TFC
344.2TF
0SSS
243TF
368.7AMH22 0629
201.8TF
20SSS
124.7TF
2.1MGOMAG COAT
0MWL
10.5TF
136.8TF
75.9TFC
53.2TF
114.1SSS
295.1TFC
46.1SSS
181.8TF
2.1SAV

Properties (7)

additional_info
630074042522201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-04-25T22:39:22-07:00
documentation
PROPIPE
is_lateral_inspection
false