- Date
- 05/06/2022
- W/O
- 951828
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00827
- PipeID
- P21326
- Time
- 1:18 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10050
- Sewer Name
- 22 SUNFLOWER TRUNK
- City
- SAN DIMAS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 15
- Purpose
- Routine Assessment
- Project
- RFIR_WO_951828_TV22166_MAY2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 22 0686
- Downstream MH
- 22 0685A
- Dir. of Survey
- Downstream
- Length Surveyed
- 69.9 ft.
- Total Length
- 69.9 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 2
- O&M Quick
- 2A00
- O&M Rating
- 22
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 25
Pipe schematic from manhole 22 0686 to 22 0685A Observation photos (4)

0 ft. - General Observation - COCKROACHES AT MH

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

12.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

69.9 ft. - General Observation - COCKROACHES AT MH