Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 20, 2022, 05:55 AM
  • 01 0966_01 0965_05202022_000312.mp4

Date
05/19/2022
W/O
952113
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00228
PipeID
P01803
Time
10:55 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10120
Sewer Name
01 WRIGHT ROAD TRUNK
City
BELL
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_952113_TV01251_MAY2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
33 in.
Upstream MH
01 0966
Downstream MH
01 0965
Dir. of Survey
Downstream
Length Surveyed
195.2 ft.
Total Length
195.2 ft.
Structural Index
3
Structural Quick
3H2G
Structural Rating
215
O&M Index
2
O&M Quick
2G00
O&M Rating
76
Overall Index
2
Overall Quick
Overall Rating
291
Pipe schematic from manhole 01 0966 to 01 0965
MH: 01 0966MH: 01 0965downstream0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 01 09660 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH2 ft. CS - Crack Spiral, from 11 to 02 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start28.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start68 ft. CS - Crack Spiral, from 11 to 02 o'clock, within 8 inches of joint: YES, Finish135 ft. FS - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start192.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish192.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish193 ft. FS - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish193 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish195.2 ft. AMH - Downstream Manhole, Survey Ends - 01 0965

Observation photos (4)

  • General Observation - ROACHES @ MH

    0 ft. - General Observation - ROACHES @ MH

  • Crack Spiral, from 11 to 02 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Spiral, from 11 to 02 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    28.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
193FS
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
192.7DAGS
68CS
2CS
0AMH01 0966
192.7FL
195.2AMH01 0965
135FS
2DAGS
2SSS
0MWL
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
28.4FL
0MWM
0MGOROACHES @ MH
193SSS

Properties (8)

additional_info
630074051922201
custom_field_three
FRACTURES
custom_field_two
2
customer
1
datetime
2022-05-19T22:55:59-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
10286