Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 20, 2022, 06:25 AM
  • 01 0963_01 0962_05202022_003931.mp4

Date
05/19/2022
W/O
952113
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00228
PipeID
P01800
Time
11:25 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10120
Sewer Name
01 WRIGHT ROAD TRUNK
City
BELL
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_952113_TV01251_MAY2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
33 in.
Upstream MH
01 0963
Downstream MH
01 0962
Dir. of Survey
Downstream
Length Surveyed
328.1 ft.
Total Length
328.1 ft.
Structural Index
2
Structural Quick
3H2L
Structural Rating
259
O&M Index
2
O&M Quick
2L00
O&M Rating
130
Overall Index
2
Overall Quick
Overall Rating
389
Pipe schematic from manhole 01 0963 to 01 0962
MH: 01 0963MH: 01 0962downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 09630 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start5.7 ft. FS - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start43.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start43.4 ft. FS - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish247.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish326 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish326 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish328.1 ft. MGO - General Observation - ROACHES @ MH328.1 ft. AMH - Downstream Manhole, Survey Ends - 01 0962

Observation photos (5)

  • General Observation - ROACHES @ MH

    0 ft. - General Observation - ROACHES @ MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

    5.7 ft. - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    43.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ROACHES @ MH

    328.1 ft. - General Observation - ROACHES @ MH

Observations (14)

DistanceCodeObservation
43.4FL
0AMH01 0963
247.9FL
43.4FS
0MWM
328.1MGOROACHES @ MH
326SSS
328.1AMH01 0962
5.7FS
326DAGS
2SSS
0MWL
0MGOROACHES @ MH
2DAGS

Properties (8)

additional_info
630074051922201
custom_field_three
MULTILPLE CONTINUOUS FRACTURES
custom_field_two
2
customer
1
datetime
2022-05-19T23:25:56-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
10286