Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 10, 2022, 06:15 AM
  • 18 0287_18 0286_05102022_003242.mp4

Date
05/09/2022
W/O
952141
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00702
PipeID
P14116
Time
11:15 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10093
Sewer Name
18 SHOEMAKER AVENUE TRUNK
City
SANTA FE SPRINGS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
30
Purpose
Routine Assessment
Project
RFIR_WO_952141_TV18148_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0287
Downstream MH
18 0286
Dir. of Survey
Downstream
Length Surveyed
360.7 ft.
Total Length
360.7 ft.
Structural Index
3
Structural Quick
3M2M
Structural Rating
360
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
360
Pipe schematic from manhole 18 0287 to 18 0286
MH: 18 0287MH: 18 0286downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 02870 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start28 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"30.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"76.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"79.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"81.2 ft. FC - Fracture Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES125.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"128.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"177.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"180.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"225.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"228.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"274.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"277.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"288.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES329.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"332.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"357.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish357.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish360.7 ft. AMH - Downstream Manhole, Survey Ends - 18 0286360.7 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES

    81.2 ft. - Fracture Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    288.6 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
288.6FL
332.1TFC
360.7AMH18 0286
0AMH18 0287
0MWL
125.4TFC
81.2FC
177.3TFC
2SAV
79.7TFC
277.6TFC
128.4TFC
30.9TFC
360.7MGOCONNECTION AT THE MH 9 OC'LOCK
357.9SAV
228.8TFC
28TFC
225.9TFC
329.1TFC
357.9SSS
0MWM
76.6TFC
274.7TFC
2SSS
180.2TFC

Properties (7)

additional_info
630074050922201
custom_field_three
AGGREGATE VISIBE/SURFACE SPALLING
custom_field_two
3
customer
1
datetime
2022-05-09T23:15:24-07:00
documentation
PROPIPE
is_lateral_inspection
false