Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 12, 2022, 06:15 AM
  • 01 0573_01 0572_05122022_014324.mp4

Date
05/11/2022
W/O
951975
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00194
PipeID
P01061
Time
11:15 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10108
Sewer Name
01 ALAMEDA STREET EXTENSION TRUNK
City
SOUTH GATE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_951975_TV01283_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
10 in.
Upstream MH
01 0572
Downstream MH
01 0573
Dir. of Survey
Upstream
Length Surveyed
433.1 ft.
Total Length
433.1 ft.
Structural Index
3
Structural Quick
3P2P
Structural Rating
430
O&M Index
2
O&M Quick
2P00
O&M Rating
172
Overall Index
2
Overall Quick
Overall Rating
602
Pipe schematic from manhole 01 0572 to 01 0573
MH: 01 0572MH: 01 0573upstream0 ft. MGO - General Observation - ROACHES @ MH0 ft. AMH - Upstream Manhole, Survey Ends - 01 05732.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish431.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start431.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES431.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start431.1 ft. MGO - General Observation - 65% MAG COAT433.1 ft. MWL - Water Level, 15 %of cross sectional area433.1 ft. MWM - Water Mark, 20 %of cross sectional area433.1 ft. AMH - Downstream Manhole, Survey Begins - 01 0572

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Observation - 65% MAG COAT

    2 ft. - General Observation - 65% MAG COAT

  • General Observation - ROACHES @ MH

    433.1 ft. - General Observation - ROACHES @ MH

Observations (12)

DistanceCodeObservation
2DAGS
2SAP
2SSS
0MWL
0MWM
431DAGS
433.1MGOROACHES @ MH
433.1AMH01 0573
431SAP
431SSS
2MGO65% MAG COAT
0AMH01 0572

Properties (7)

additional_info
630063051122201
custom_field_three
AGGREGATE PROJECTING
custom_field_two
2
customer
1
datetime
2022-05-11T23:15:07-07:00
documentation
PRO PIPE
is_lateral_inspection
false