Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 3, 2022, 06:35 AM
  • 18 0068_18 0067_05032022_004109.mp4

Date
05/02/2022
W/O
951925
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13882
Time
11:35 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10087
Sewer Name
18 SANTA FE STREET TRUNK
City
S.WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_951925_TV18083_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0067
Downstream MH
18 0068
Dir. of Survey
Upstream
Length Surveyed
93.6 ft.
Total Length
93.6 ft.
Structural Index
3
Structural Quick
3C00
Structural Rating
54
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
54
Pipe schematic from manhole 18 0067 to 18 0068
MH: 18 0067MH: 18 0068upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 00681.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish91.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start91.5 ft. MGO - General Observation - MAG COAT93.6 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK93.6 ft. MWL - Water Level, 10 %of cross sectional area93.6 ft. AMH - Downstream Manhole, Survey Begins - 18 006793.6 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
2.1SAV
91.9SAV
0MGOCONNECTION AT THE MH 3 OC'LOCK
0MWL
93.6AMH18 0068
2.1MGOMAG COAT
0AMH18 0067
0MWM

Properties (7)

additional_info
630074050222201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-05-02T23:35:00-07:00
documentation
PROPIPE
is_lateral_inspection
false