Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 5, 2022, 10:20 AM
  • 18 0081_18 1097_05052022_043612.mp4

Date
05/05/2022
W/O
951925
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13900
Time
3:20 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10090
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_951925_TV18083_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0081
Downstream MH
18 1097
Dir. of Survey
Downstream
Length Surveyed
52.2 ft.
Total Length
52.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 0081 to 18 1097
MH: 18 0081MH: 18 1097downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 00810 ft. MWM - Water Mark, 25 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start51.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish51.6 ft. MGO - General Observation - CONNECTION AT THE MH 12 OC'LOCK52.2 ft. AMH - Downstream Manhole, Survey Ends - 18 1097

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
2.1SAV
51.5SAV
52.2AMH18 1097
51.6MGOCONNECTION AT THE MH 12 OC'LOCK
0MWL
0MGOCONNECTION AT THE MH 9 OC'LOCK
0AMH18 0081
0MWM

Properties (7)

additional_info
630074050422202
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-05-05T03:20:48-07:00
documentation
PROPIPE
is_lateral_inspection
false