- Date
- 05/03/2022
- W/O
- 951925
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00698
- PipeID
- P13889
- Time
- 12:30 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10087
- Sewer Name
- 18 SANTA FE STREET TRUNK
- City
- S.WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_951925_TV18083_MAY2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 18 0073
- Downstream MH
- 18 0074
- Dir. of Survey
- Upstream
- Length Surveyed
- 307.5 ft.
- Total Length
- 307.5 ft.
- Structural Index
- 3
- Structural Quick
- 3K00
- Structural Rating
- 183
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 185
Pipe schematic from manhole 18 0073 to 18 0074 Observation photos (3)

2.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

91.4 ft. - Tap Saddle Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

290.8 ft. - Tap Saddle, at 12 o'clock, -, within 8 inches of joint: NO, 6"