Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2022, 08:01 AM
  • 18 0123_18 0122_04272022_021512.mp4

Date
04/27/2022
W/O
951925
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13944
Time
1:01 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10081
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_951925_TV18083_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0122
Downstream MH
18 0123
Dir. of Survey
Upstream
Length Surveyed
335.5 ft.
Total Length
335.5 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
204
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
204
Pipe schematic from manhole 18 0122 to 18 0123
MH: 18 0122MH: 18 0123upstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Ends - 18 01230.1 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED1.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish57.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"63.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"86.6 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES108.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"114.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"157.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"163.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"208.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"214.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"216.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES256.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"257.6 ft. TS - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"262.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"333.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start335.5 ft. MWL - Water Level, 5 %of cross sectional area335.5 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK335.5 ft. MWM - Water Mark, 10 %of cross sectional area335.5 ft. AMH - Downstream Manhole, Survey Begins - 18 0122

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    77.9 ft. - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    118.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    248.9 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
248.9FL
77.9TS
272.2TFC
0MWL
2.3SAV
335.5MGOCONNECTION AT THE MH 3 OC'LOCK
72.9TF
220.8TF
226.9TFC
0MGOCONNECTION AT THE MH 9 OC'LOCK
278.3TFC
127.2TF
121.1TF
0MWM
335.4MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED
335.5AMH18 0123
178.4TF
172.3TFC
0AMH18 0122
118.9FL
333.9SAV
79.1TFC

Properties (7)

additional_info
630074042622201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-04-27T01:01:56-07:00
documentation
PROPIPE
is_lateral_inspection
false