Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2022, 06:40 AM
  • 18 0118_18 0987_04272022_004916.mp4

Date
04/26/2022
W/O
951925
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13939
Time
11:40 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10081
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_951925_TV18083_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0118
Downstream MH
18 0987
Dir. of Survey
Downstream
Length Surveyed
181 ft.
Total Length
181 ft.
Structural Index
3
Structural Quick
3F11
Structural Rating
106
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
106
Pipe schematic from manhole 18 0118 to 18 0987
MH: 18 0118MH: 18 0987downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 01182.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"19.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"64.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"70.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"113.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"119.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"161.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"166 ft. CC - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES167.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"178.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish181 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK181 ft. AMH - Downstream Manhole, Survey Ends - 18 0987

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES

    166 ft. - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
113.2TF
0MWM
181MGOCONNECTION AT THE MH 9 OC'LOCK
166CC
2.6SAV
0MWL
64.6TF
0AMH18 0118
13.1TF
161.4TFC
70.6TFC
178.6SAV
19.3TFC
167.6TFC
119.4TFC
181AMH18 0987

Properties (7)

additional_info
630074042622201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-04-26T23:40:55-07:00
documentation
PROPIPE
is_lateral_inspection
false