Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2022, 08:38 AM
  • 18 0116_18 0115_04272022_025422.mp4

Date
04/27/2022
W/O
951925
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13936
Time
1:38 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10081
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_951925_TV18083_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0116
Downstream MH
18 0115
Dir. of Survey
Downstream
Length Surveyed
274.7 ft.
Total Length
274.7 ft.
Structural Index
3
Structural Quick
413O
Structural Rating
250
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
250
Pipe schematic from manhole 18 0116 to 18 0115
MH: 18 0116MH: 18 0115downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 01160 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. MGO - General Observation - CONNECTION AT THE MH 6 OC'LOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start16.8 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES55.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"61.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"96.6 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES103.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"109.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"127.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES142 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start155.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"161.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"205.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"212 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"256.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"262.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"273.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish273.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish274.7 ft. AMH - Downstream Manhole, Survey Ends - 18 0115

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    16.8 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    96.6 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    127.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
0AMH18 0116
0MGOCONNECTION AT THE MH 9 OC'LOCK
96.6FL
0MGOCONNECTION AT THE MH 6 OC'LOCK
61.8TF
2.1SAV
127.8FL
274.7AMH18 0115
109.7TF
205.8TFC
16.8FM
0MWM
142FL
256.3TF
273.8FL
161.7TFC
103.5TF
273.8SAV
262.7TF
212TF
0MWL
55.3TFC
155.4TFC

Properties (7)

additional_info
630074042622201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-04-27T01:38:57-07:00
documentation
PROPIPE
is_lateral_inspection
false