Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2022, 05:02 AM
  • 18 0111_18 0110_04262022_231532.mp4

Date
04/26/2022
W/O
951925
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13931
Time
10:02 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10081
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_951925_TV18083_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0111
Downstream MH
18 0110
Dir. of Survey
Downstream
Length Surveyed
227.3 ft.
Total Length
227.3 ft.
Structural Index
3
Structural Quick
4E3H
Structural Rating
265
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
265
Pipe schematic from manhole 18 0111 to 18 0110
MH: 18 0111MH: 18 0110downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 01110 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start37 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"39 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES43 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"62.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES69.2 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start86.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"92.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"138.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"143.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"187.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"193 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"225.2 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish225.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish227.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0110227.3 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    39 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    69.2 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

Observations (20)

DistanceCodeObservation
193TFC
143.9TFC
0AMH18 0111
86.4TF
227.3AMH18 0110
0MGOCONNECTION AT THE MH 3 OC'LOCK
39FL
138.1TF
0MWM
2.5SAV
43TFC
69.2FM
62.7FL
187.2TF
37TF
227.3MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
225.2FM
0MWL
225.2SAV
92.3TFC

Properties (7)

additional_info
630074042622201
custom_field_three
AGGREGATE VISIBLE/FRACTURE'S
custom_field_two
3
customer
1
datetime
2022-04-26T22:02:55-07:00
documentation
PROPIPE
is_lateral_inspection
false