Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 11, 2022, 09:31 AM
  • 18 0451_18 0450_05112022_035151.mp4

Date
05/11/2022
W/O
951858
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00675
PipeID
P14302
Time
2:31 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10095
Sewer Name
18 FLORENCE AVENUE TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_951858_TV18097_MAY2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0450
Downstream MH
18 0451
Dir. of Survey
Upstream
Length Surveyed
317.2 ft.
Total Length
317.2 ft.
Structural Index
3
Structural Quick
4B3F
Structural Rating
167
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
167
Pipe schematic from manhole 18 0450 to 18 0451
MH: 18 0450MH: 18 0451upstream0 ft. MGO - General Observation - CONNECTION AT THE MH 12 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Ends - 18 04513.7 ft. FM - Fracture Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES, Finish31 ft. FM - Fracture Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES, Start31 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish57.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"84.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"108.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"127.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"156.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"182 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"191 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start206.6 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES207.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"211.9 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES217.3 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES233.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"247.9 ft. CM - Crack Multiple, from 01 to 02 o'clock, within 8 inches of joint: YES253.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish259.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"282.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"305 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start305.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"317.2 ft. MWL - Water Level, 15 %of cross sectional area317.2 ft. AMH - Downstream Manhole, Survey Begins - 18 0450317.2 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (7)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    12.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 01 to 02 o'clock, within 8 inches of joint: YES

    69.3 ft. - Crack Multiple, from 01 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    99.9 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    105.3 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    110.6 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    126.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES, Start

    286.2 ft. - Fracture Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (26)

DistanceCodeObservation
11.6TFC
57.8TFC
233.1TFC
208.3TFC
126.2CM
99.9FL
0MWL
259.3TFC
286.2FM
313.5FM
105.3FL
34.3TFC
161TFC
317.2MGOCONNECTION AT THE MH 12 OC'LOCK
69.3CM
286.2CM
317.2AMH18 0451
0AMH18 0450
135.2TFC
189.5TFC
110.6CL
64.1FM
0MWM
109.4TFC
12.2FM
83.8TFC

Properties (7)

additional_info
630074051022202
custom_field_three
MULTIPLE CRACKS/FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-05-11T02:31:55-07:00
documentation
PROPIPE
is_lateral_inspection
false