- Date
- 05/12/2022
- W/O
- 951858
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00675
- PipeID
- P14278
- Time
- 12:03 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10096
- Sewer Name
- 18 FLORENCE AVENUE TRUNK
- City
- SANTA FE SPRINGS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 19
- Purpose
- Routine Assessment
- Project
- RFIR_WO_951858_TV18097_MAY2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- 18 0429
- Downstream MH
- 18 0430
- Dir. of Survey
- Upstream
- Length Surveyed
- 108.4 ft.
- Total Length
- 108.4 ft.
- Structural Index
- 3
- Structural Quick
- 3C2C
- Structural Rating
- 103
- O&M Index
- 2
- O&M Quick
- 2C00
- O&M Rating
- 42
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 145
Pipe schematic from manhole 18 0429 to 18 0430 Observation photos (3)

3 ft. - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

9.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start