Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 24, 2022, 06:42 AM
  • A 0208_A 0207_02232022_224811.mp4

Date
02/23/2022
W/O
936486
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00323
PipeID
P08144
Time
10:42 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9745
Sewer Name
A JOA-1A LOS COYOTES WRP INTERCEPTOR
City
SOUTH GATE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
29
Purpose
Routine Assessment
Project
RFIR_WO_936486_TV02346_FEB2022
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
75 in.
Width
39 in.
Upstream MH
A 0208
Downstream MH
A 0207
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
4
Overall Quick
Overall Rating
15
Pipe schematic from manhole A 0208 to A 0207
MH: A 0208MH: A 0207downstream0 ft. AMH - Upstream Manhole, Survey Begins - A 02080 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. MWL - Water Level, 70 %of cross sectional area2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES2 ft. MGO - General Observation - MAG COATING2 ft. MSA - Survey Abandoned - VIEW OF THE DWN LEG OF THE UP MH2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES2 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

Observation photos (5)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES

  • General Observation - MAG COATING

    2 ft. - General Observation - MAG COATING

  • Survey Abandoned - VIEW OF THE DWN LEG OF THE UP MH

    2 ft. - Survey Abandoned - VIEW OF THE DWN LEG OF THE UP MH

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
2SSS
0AMHA 0208
0MWM
0MWL
2MGOMAG COATING
2MSAVIEW OF THE DWN LEG OF THE UP MH
2SAP
2SRV

Properties (8)

additional_info
63009802322201
custom_field_three
REINFORCEMENT VISBLE, AGGREGATE PROJECTING
custom_field_two
2
customer
1
datetime
2022-02-23T22:42:27-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
28636