- Date
- 02/23/2022
- W/O
- 936486
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00323
- PipeID
- P08151
- Time
- 2:37 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9744
- Sewer Name
- A JOA-1A LOS COYOTES WRP INTERCEPTOR
- City
- SOUTH GATE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 26
- Purpose
- Routine Assessment
- Project
- RFIR_WO_936486_TV02346_FEB2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 75 in.
- Width
- 39 in.
- Upstream MH
- A 0215
- Downstream MH
- A 0214
- Dir. of Survey
- Downstream
- Length Surveyed
- 129 ft.
- Total Length
- 129 ft.
- Structural Index
- 3
- Structural Quick
- 3D2D
- Structural Rating
- 125
- O&M Index
- 4
- O&M Quick
- 4D00
- O&M Rating
- 92
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 217
Pipe schematic from manhole A 0215 to A 0214 Observation photos (5)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - General Observation - MAG COATING

17.3 ft. - Alignment Right, 40 %, Start

62.9 ft. - Alignment Left, 40 %, Start