- Date
- 05/10/2022
- W/O
- 951809
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00675
- PipeID
- P14944
- Time
- 11:15 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10094
- Sewer Name
- 18 FLORENCE AVENUE TRUNK
- City
- SANTA FE SPRINGS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- RFIR_WO_951809_TV18203_MAY2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 18 1083
- Downstream MH
- 18 1084
- Dir. of Survey
- Upstream
- Length Surveyed
- 323.1 ft.
- Total Length
- 323.1 ft.
- Structural Index
- 4
- Structural Quick
- 4F33
- Structural Rating
- 153
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 153
Pipe schematic from manhole 18 1083 to 18 1084 Observation photos (5)

81.9 ft. - Fracture Spiral, from 07 to 11 o'clock, within 8 inches of joint: YES

112.3 ft. - Fracture Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES

128.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

133.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

145.5 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start