Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 11, 2022, 05:57 AM
  • 18 1080_18 1079_05112022_001350.mp4

Date
05/10/2022
W/O
951809
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00675
PipeID
P14940
Time
10:57 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10094
Sewer Name
18 FLORENCE AVENUE TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_951809_TV18203_MAY2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 1080
Downstream MH
18 1079
Dir. of Survey
Downstream
Length Surveyed
325 ft.
Total Length
325 ft.
Structural Index
4
Structural Quick
4H34
Structural Rating
200
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
200
Pipe schematic from manhole 18 1080 to 18 1079
MH: 18 1080MH: 18 1079downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 108022.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES28 ft. FS - Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES78.2 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES83.7 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES88.4 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start321.8 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish325 ft. AMH - Downstream Manhole, Survey Ends - 18 1079325 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (4)

  • Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

    28 ft. - Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

    78.2 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    83.7 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    88.4 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
78.2FS
22.5FL
28FS
0MWM
0MWL
83.7FL
321.8FM
88.4FM
325AMH18 1079
0AMH18 1080
325MGOCONNECTION AT THE MH 9 OC'LOCK

Properties (8)

additional_info
630074051022201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-05-10T22:57:57-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
27555