Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 11, 2022, 07:01 AM
  • 18 1079_18 1078_05112022_011014.mp4

Date
05/11/2022
W/O
951809
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00675
PipeID
P14939
Time
12:01 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10094
Sewer Name
18 FLORENCE AVENUE TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_951809_TV18203_MAY2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 1079
Downstream MH
18 1078
Dir. of Survey
Downstream
Length Surveyed
335.2 ft.
Total Length
335.2 ft.
Structural Index
4
Structural Quick
4K00
Structural Rating
236
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
236
Pipe schematic from manhole 18 1079 to 18 1078
MH: 18 1079MH: 18 1078downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 10790 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK37.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start208.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"332.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish335.2 ft. AMH - Downstream Manhole, Survey Ends - 18 1078

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    37.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWM
208.4TFA
0MWL
332.1FM
37.7FM
0AMH18 1079
335.2AMH18 1078
0MGOCONNECTION AT THE MH 9 OC'LOCK

Properties (8)

additional_info
630074051022201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-05-11T00:01:15-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
27555