Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 19, 2022, 08:19 AM
  • 15 1044_15 0060_05192022_022849.mp4

Date
05/19/2022
W/O
951556
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00622
PipeID
P11955
Time
1:19 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10118
Sewer Name
15 PUENTE TRUNK
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_951556_TV15220_MAY2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0060
Downstream MH
15 1044
Dir. of Survey
Upstream
Length Surveyed
146.9 ft.
Total Length
146.9 ft.
Structural Index
3
Structural Quick
413E
Structural Rating
88
O&M Index
2
O&M Quick
2E00
O&M Rating
58
Overall Index
3
Overall Quick
Overall Rating
146
Pipe schematic from manhole 15 0060 to 15 1044
MH: 15 0060MH: 15 1044upstream0 ft. MGO - General Observation - STOP LOG AT MH0 ft. AMH - Upstream Manhole, Survey Ends - 15 10440 ft. MGO - General Observation - COCKROACHES AT MH1.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish1.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish102.7 ft. B - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES142.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start144.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start146.9 ft. MWL - Water Level, 10 %of cross sectional area146.9 ft. AMH - Downstream Manhole, Survey Begins - 15 0060146.9 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (5)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 11 to 01 o'clock, within 8 inches of joint: YES

    44.2 ft. - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES

  • General Observation - STOP LOG AT MH

    146.9 ft. - General Observation - STOP LOG AT MH

  • General Observation - COCKROACHES AT MH

    146.9 ft. - General Observation - COCKROACHES AT MH

Observations (11)

DistanceCodeObservation
146.9MGOSTOP LOG AT MH
4CM
145.3DAGS
145.3CM
2DAGS
0MWL
146.9AMH15 1044
0AMH15 0060
146.9MGOCOCKROACHES AT MH
44.2B
0MWM

Properties (7)

additional_info
630063051822202
custom_field_three
BROKEN PIPE/CRACKS
custom_field_two
2
customer
1
datetime
2022-05-19T01:19:16-07:00
documentation
PRO PIPE
is_lateral_inspection
false