Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2022, 07:03 AM
  • 08 0547_08 0546_05182022_011726.mp4

Date
05/18/2022
W/O
951936
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00021
PipeID
P00609
Time
12:03 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10115
Sewer Name
08 VICTORIA STREET TRUNK
City
RANCHO DOMINGUEZ
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_951936_TV08157_MAY2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
12 in.
Upstream MH
08 0547
Downstream MH
08 0546
Dir. of Survey
Downstream
Length Surveyed
280.7 ft.
Total Length
280.7 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
120
O&M Index
2
O&M Quick
2J00
O&M Rating
110
Overall Index
2
Overall Quick
Overall Rating
230
Pipe schematic from manhole 08 0547 to 08 0546
MH: 08 0547MH: 08 0546downstream0 ft. MGO - General Observation - COCKROACHES AT MH0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 05470 ft. MGO - General Observation - CONNECTION AT MH 3 AND 9 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start33.5 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"39.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES84.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start278.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish278.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish280.7 ft. AMH - Downstream Manhole, Survey Ends - 08 0546280.7 ft. MGO - General Observation - COCKROACHES AT MH

Observation photos (5)

  • General Observation - COCKROACHES AT MH

    0 ft. - General Observation - COCKROACHES AT MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    39.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    84.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES AT MH

    280.7 ft. - General Observation - COCKROACHES AT MH

Observations (13)

DistanceCodeObservation
0MGOCOCKROACHES AT MH
0MWM
280.7AMH08 0546
33.5TBA
0AMH08 0547
278.7DAGS
278.7CM
0MGOCONNECTION AT MH 3 AND 9 O'CLOCK
2DAGS
280.7MGOCOCKROACHES AT MH
39.6CM
0MWL
84.3CM

Properties (7)

additional_info
630063051722203
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-05-18T00:03:52-07:00
documentation
PRO PIPE
is_lateral_inspection
false