Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2022, 07:51 AM
  • 08 0544_08 0543_05182022_020727.mp4

Date
05/18/2022
W/O
951936
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00021
PipeID
P00606
Time
12:51 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10115
Sewer Name
08 VICTORIA STREET TRUNK
City
RANCHO DOMINGUEZ
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_951936_TV08157_MAY2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
12 in.
Upstream MH
08 0544
Downstream MH
08 0543
Dir. of Survey
Downstream
Length Surveyed
270.5 ft.
Total Length
270.5 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
114
O&M Index
2
O&M Quick
2J00
O&M Rating
106
Overall Index
2
Overall Quick
Overall Rating
220
Pipe schematic from manhole 08 0544 to 08 0543
MH: 08 0544MH: 08 0543downstream0 ft. MGO - General Observation - COCKROACHES AT MH0 ft. AMH - Upstream Manhole, Survey Begins - 08 05440 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start81.8 ft. CM - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES84.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start268.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish268.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish270.5 ft. AMH - Downstream Manhole, Survey Ends - 08 0543270.5 ft. MGO - General Observation - COCKROACHES AT MH270.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK270.5 ft. MGO - General Observation - Connection at MH 3 O'clock capped

Observation photos (5)

  • General Observation - COCKROACHES AT MH

    0 ft. - General Observation - COCKROACHES AT MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

    81.8 ft. - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    84.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES AT MH

    270.5 ft. - General Observation - COCKROACHES AT MH

Observations (13)

DistanceCodeObservation
0MGOCOCKROACHES AT MH
268.7CM
0AMH08 0544
81.8CM
268.7DAGS
270.5AMH08 0543
0MWL
270.5MGOCOCKROACHES AT MH
2DAGS
270.5MGOCONNECTION AT MH 9 O'CLOCK
270.5MGOConnection at MH 3 O'clock capped
0MWM
84.5CM

Properties (7)

additional_info
630063051722203
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-05-18T00:51:50-07:00
documentation
PRO PIPE
is_lateral_inspection