Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 27, 2022, 06:35 AM
  • 29 0322_29 0321_05272022_011107.mp4

Date
05/26/2022
W/O
951819
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01024
PipeID
P24339
Time
11:35 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10157
Sewer Name
29 PACIFIC COAST HIGHWAY TRUNK
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_951819_TV29083_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0321
Downstream MH
29 0322
Dir. of Survey
Upstream
Length Surveyed
328 ft.
Total Length
328 ft.
Structural Index
3
Structural Quick
413M
Structural Rating
214
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
214
Pipe schematic from manhole 29 0321 to 29 0322
MH: 29 0321MH: 29 0322upstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 29 03222.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish15.6 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES38.7 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES119.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"129.4 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES147.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES201.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES209.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"221.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES249.9 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES292.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"311.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start311.7 ft. MMC - Material Change, Concrete pipe (non-reinfored)315.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish315.6 ft. MMC - Material Change, Vitrified clay pipe325.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start328 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK328 ft. MWM - Water Mark, 10 %of cross sectional area328 ft. AMH - Downstream Manhole, Survey Begins - 29 0321328 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (11)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Material Change, Vitrified clay pipe

    12.4 ft. - Material Change, Vitrified clay pipe

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    16.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Material Change, Concrete pipe (non-reinfored)

    16.3 ft. - Material Change, Concrete pipe (non-reinfored)

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    78.1 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    106.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    126.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    180.7 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    198.6 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    289.3 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    312.4 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
180.7FL
0MGOCONNECTION AT MH 9 O'CLOCK
35.5TF
12.4SAV
12.4MMC
0MWM
0AMH29 0321
2.1SAV
0MWL
16.3SAV
16.3MMC
289.3FL
106.3FL
198.6FL
328MGOCONNECTION AT MH 9 O'CLOCK
126.6FL
118.1TF
328AMH29 0322
208.1TF
78.1FL
325.4SAV
312.4FM

Properties (7)

additional_info
630063052622202
custom_field_three
AGGREGATE VISIBLE/ FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-05-26T23:35:50-07:00
documentation
PROPIPE
is_lateral_inspection
false