- Date
- 05/16/2022
- W/O
- 951823
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00708
- PipeID
- P14696
- Time
- 10:53 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10097
- Sewer Name
- 18 SO WHITTIER OUTFALL TR, SECT 6
- City
- SANTA FE SPRINGS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_951823_TV18183_MAY2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 18 0832
- Downstream MH
- 18 0833
- Dir. of Survey
- Upstream
- Length Surveyed
- 292.9 ft.
- Total Length
- 292.9 ft.
- Structural Index
- 4
- Structural Quick
- 4C31
- Structural Rating
- 87
- O&M Index
- 1
- O&M Quick
- 1200
- O&M Rating
- 2
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 89
Pipe schematic from manhole 18 0832 to 18 0833 Observation photos (4)

3.6 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

6.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

110.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

118.1 ft. - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YES